TM 5-3895-346-14
HYDROSTATIC SYSTEM
PUMP REPAIR
Be certain to keep the plastic shims with the proper trunnion to insure satisfactory bearing adjustment after
reassembly (refer to Fig. 34).
Figure 34.
Figure 35.
After both trunnion assemblies have been removed, the swashplate assembly can be removed from the pump
housing (refer to Fig. 35).
Layout of parts showing swashplate, servo pistons and springs, feedback link and trunnions (refer to Fig. 36).
Figure 36.
Figure 37.
When installing the swashplate assembly into the housing, the feedback link must be laid back along the top of
the swashplate so it can be reached through the opening for the control valve (refer to Fig. 37).
After installing swashplate be certain feedback link is accessible (refer to Fig. 38).
544