TM 5-3895-383-24
Testing and Adjusting
Troubleshooting
Troubleshooting can be difficult. The Troubleshooting Index
gives a list of possible problems. To make a repair to a
problem, make reference to the cause and correction on the
pages that follow.
This list of problems, causes, and corrections will only give an
indication of where a possible problem can be, and what
repairs a needed. Normally, more or other repair work is
needed beyond the recommendations in the list.
Remember that a problem is not normally caused only by one
part, but by the relation of one part with other parts. This list is
only a guide and cannot give all possible problems and
corrections. The serviceman must find the problem and its
source, then make the necessary repairs.
NOTE:
For each problem, a list of possible causes and
corrections is given. The list of probable causes
and corrections should be performed in numeric
sequence.
Troubleshooting Problem List
1.
Contactor Switch For Water Temperature Activates At
Wrong Temperature.
2.
Contactor Switch For Oil Pressure Does Not
Activate Shutoff Solenoid.
Troubleshooting Problems
Problem 1: Contactor Switch For Water
Temperature Activates At Wrong Temperature.
Probable Cause:
1.
Wrong Setting Of Switch
Make a test of temperature setting and if
necessary install new contactor switch with
correct setting. See specifications.
Problem 2: Contactor Switch For Oil Pressure Does
Not Activate Shutoff Solenoid.
Probable Cause:
1.
Wrong Connections
Check connections, wiring and correct where
necessary.
2.
Wrong Setting Of Switch
Make a test of temperature setting and if
necessary install new contactor switch with
correct setting. See specifications.
7-25