TM 5-3895-382-24
2-8.
HYDRAULIC OIL SAMPLING (CONT)
(1)
Remove five screws (1), washers (2), and panel (3) from frame assembly (4).
(2)
Remove hydraulic oil sampling valve drain cap (5) from hydraulic oil sampling valve (6).
(3)
Start engine (TM 5-3895-382-10).
(4)
Place container with 1 qt (0.91) minimum capacity under hydraulic oil sampling valve (6).
(5)
Turn and hold knurled knob (7) in direction of arrow until hydraulic oil sample is collected. Release knob when
sample has been collected.
(6)
Install hydraulic oil sampling valve drain cap (5) on hydraulic oil sampling valve (6).
(7)
Shut engine OFF (TM 5-3895-382-10).
(8)
Install panel (3) on frame assembly (4) with five washers (2) and screws (1).
(9)
Submit hydraulic oil sample to your local Army Oil Analysis Program (AOAP) laboratory for analysis.
NOTE
Follow-on Maintenance:
·
Unlock steering pin (TM 5-3895-382-10).
·
Check hydraulic oil level (TM 5-3895-382-10).
·
Close right side door assembly (TM 5-3895-382-10).
·
Remove chocks.
END OF TASK
2-26