TM 5-3895-379-23
OPERATOR PLATFORM AND OPERATOR STATION REPLACEMENT - CONTINUED
0202 00
REMOVAL
CAUTION
Cap and plug all lines and fittings immediately to prevent any contaminants from entering the system.
Tag all hydraulic lines and electrical wires as they are removed or disconnected.
NOTE
Tag and mark all hydraulic lines as they are removed for installation purposes. Cap and plug all lines
and fittings to prevent any contaminants from entering the system.
1.
Release pressure in hydraulic system by slowly loosening the fill cap on the top of the hydraulic oil tank.
2.
Disconnect wiring harnesses (1) and (2).
3.
Remove two nuts (3) and clamp (4).
1
4
2
3
401-2199
4.
Disconnect hose assemblies (5) and (6).
5
6
401-2206
0202 00-2