TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 3. Hydraulic Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Hydraulic Oil Temperature Is High 3. Check fan assembly and guard for 1. If fan assembly and guard are
1.
looseness or damage such as
loose or damaged, tighten or
(Warning Light and Warning Horn On)
cracked or missing fan blade(s),
replace loose or damaged parts
- Continued.
loose nuts and screws, bent or
cracked fan pulley or damage or
wear resulting from extreme fan
blade wobble.
2. If fan assembly and guard are not
loose or damaged, lower operator
supervisor.
WARNING
When working on a running engine, provide shielding for exposed
rotating parts. Tools, clothing or hands can get caught and cause
injury.
Open right-side door assembly (TM 1. If filter indicator is in red zone,
2.
Hydraulic Oil Pressure Is Low
(Warning Light and Warning Horn
5-3895-379-10) and check hydraulic
On).
oil filter indicator with engine
running at high idle.
2. If filter indicator is not in red zone,
close right-side door assembly and
notify supervisor.
FAN
BLADE
RED ZONE
WHITE FILTER INDICATOR
(CB534B ONLY)
HYDRAULIC
OIL FILTER
INDICATOR
401-032