TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Warning and Indicator Lights Do Not 11. Touch positive (+) probe of 1. If multimeter does not measure
5.
multimeter to terminal 87A and
zero ohms between terminals 30
Operate - Continued.
negative (-) probe of multimeter
and 87A, replace warning light
to terminal 30 of warning light
relay. Multimeter should measure
zero ohms. Move positive (+) 2. If multimeter does not measure
infinite ohms between terminals
probe of multimeter to terminal
30 and 87, replace warning light
87 while negative (-) probe of
multimeter stays at terminal 30 of
should measure infinite ohms.
install functional light relay (WP
12. Check for good ground to 1. If multimeter does not measure
warning light relay. Touch
zero ohms at both terminals 2 and
positive (+) probe of multimeter
4, repair or replace wire 200-BK
to terminal 2 (wire 200-BK) of
harness connector and negative
(-) probe to good ground. 2. If multimeter does read zero ohms,
go to Step 13.
Multimeter should measure zero
ohms. Move positive (+) probe of
multimeter to terminal 4 (wire
200-BK) of harness connector
and negative (-) probe to good
ground. Multimeter
should
measure zero ohms.
PANEL
ASSEMBLY
SCREW
WASHER
SCREW
WASHER
RELAY
TERMINALS
2
1
HARNESS
4
CONNECTOR
3
5
OPERATOR
FUNCTIONAL
401-200
STATION
LIGHT RELAY
0006 00-69