TM 5-3895-379-23-2
0274
REMOVAL - Continued
2
1
7
6
5
3
4
M0265SWR
Figure 2. Water Spray Check Valve Removal.
END OF TASK
CLEAN AND INSPECTION
1.
Clean check valve, check valve body, and check valve adapter in non-sudsing detergent and water. Remove
difficult deposits with a cleaning brush.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may cause injury or death. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, user must wear protective goggles or face
shield.
2.
Use cleaning cloth or compressed air to dry metal parts.
3.
Check check valve for corrosion or excessive wear.
4.
Check check valve body and check valve body adapter for nicks, cracks, crossed threads, or corrosion.
5.
Replace damaged parts.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00212)