TM 5-3895-379-23-2
0255
REMOVAL - Continued
1
5
2
3
4
5
6
M0824SWR
Figure 2. Hydraulic Oil Sampling Valve Removal.
END OF TASK
INSTALLATION
1.
Install new O-ring (Figure 3, Item 5) in tee (Figure 3, Item 4).
2.
Apply sealing compound to threads of tee (Figure 3, Item 4) and install new preformed packing
(Figure 3, Item 3) and cap (Figure 3, Item 2) on tee.
3.
Apply sealing compound to threads of tee (Figure 3, Item 4) and install new O-ring (Figure 3, Item 5) and boss
reducer (Figure 3, Item 6) on tee.
4.
If removed, apply sealing compound to threads of tee (Figure 3, Item 4) and install tee in hydraulic oil pump
(Figure 3, Item 1).
1
5
2
3
4
5
6
M1133SWR
Figure 3. Hydraulic Oil Sampling Valve Installation.
03/15/2011Rel(1.8)root(maintwp)wpno(M00193)