• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
VIBRATORY CONTROL SOLENOID REPLACEMENT
Figure 2. Vibratory Control Solenoid Installation

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 2 Page Navigation
  164    165    166    167    168  169  170    171    172    173    174  
img
.
TM 5-3895-379-23-2
0251
REMOVAL
1.
Remove two screws (Figure 1, Item 1) that fasten two electrical connectors (Figure 1, Item 2) to two solenoids
(Figure 1, Item 6).
2.
Remove two electrical connectors (Figure 1, Item 2) from two solenoids (Figure 1, Item 6).
3.
Remove four bolts (Figure 1, Item 4) and one bolt (Figure 1, Item 5) from vibratory control valve body
(Figure 1, Item 3).
4.
Remove vibratory control valve body (Figure 1, Item 3) from roller.
5.
Remove two solenoids (Figure 1, Item 6) from vibratory control valve body (Figure 1, Item 3).
1
2
3
4
5
6
M0816SWR
Figure 1.
Vibratory Control Solenoid Removal.
END OF TASK
0251-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00189)