• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Vibration Sensor Removal.
Figure 3. Vibration Sensor Adjustment

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  959    960    961    962    963  964  965    966    967    968    969  
img
.
TM 5-3895-379-23-1
0184
INSTALLATION
1.
Install spacer (Figure 2, Item 8) and vibration sensor (Figure 2, Item 7) in plate (Figure 2, Item 1). Do not tighten
nut (Figure 2, Item 6).
2.
Install vibration motor hydraulic line (Figure 2, Item 4) on elbow (Figure 2, Item 5).
3.
Connect connector (Figure 2, Item 2) to vibratory sensor connector (Figure 2, Item 3).
1
2
8
7
6
3
4
5
M1309SWR
Figure 2. Vibration Sensor Installation.
4.
Adjust sensor. Refer to ADJUSTMENT in this work package.
END OF TASK
0184-3
03/15/2011Rel(1.8)root(maintwp)wpno(M00122)