TM 5-3895-379-23-1
0185
INSTALLATION
1.
Apply sealing compound to threads of hydraulic oil temperature sensor (Figure 2, Item 2) and install in hydraulic
oil tank fitting (Figure 2, Item 1). Tighten sensor to 26-33 lb-ft (35-45 Nm).
2.
Position two wires (Figure 2, Item 4) on hydraulic oil temperature sensor (Figure 2, Item 2) and tighten two
screws (Figure 2, Item 3).
1
2
3
4
3
4
M1050SWR
Figure 2.
Temperature Sensor Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
2.
Close left-side door assembly. (TM 5-3895-379-10)
3.
Start engine and check for leaks. (TM 5-3895-379-10)
4.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE