Figure 1. Water Temperature Sending Unit Removal
FUEL LEVEL SENDING UNIT REPLACEMENT

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  953    954    955    956    957  958  959    960    961    962    963  
img
. .
TM 5-3895-379-23-1
0182
INSTALLATION
1.
Coat threads of water temperature sending unit (Figure 2, Item 5) with sealing compound.
2.
Install water temperature sending unit (Figure 2, Item 5) and O-ring (Figure 2, Item 4) in water intake manifold
(Figure 2, Item 3). Tighten water temperature sending unit 32-44 lb-ft (44-60 Nm).
3.
Connect connector (Figure 2, Item 1) to water temperature sending unit connector (Figure 2, Item 2).
1
2
3
4
5
M0955SWR
Figure 2. Water Temperature Sending Unit Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Fill cooling system to proper level. (WP 0139)
2.
Close right-side door assembly. (TM 5-3895-379-10)
3.
Start engine and check for coolant leaks. (TM 5-3895-379-10)
4.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE