BACKUP ALARM SENDING UNIT REPLACEMENT
Figure 4. Backup Alarm Sending Unit Installation.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  949    950    951    952    953  954  955    956    957    958    959  
img
.
TM 5-3895-379-23-1
0181
REMOVAL - Continued
4.
Remove two screws (Figure 2, Item 6), lockwashers (Figure 2, Item 5), and wires (Figure 2, Items 2 and 4)
from backup alarm sending unit (Figure 2, Item 3). Discard lockwashers.
5.
Remove backup alarm sending unit (Figure 2, Item 3) from adapter (Figure 2, Item 1).
1
2
3
6
5
4
M0953SWR
Figure 2. Backup Alarm Sending Unit Removal.
END OF TASK
INSTALLATION
1.
Apply sealing compound to threads of backup alarm sending unit (Figure 3, Item 3).
2.
Install backup alarm sending unit (Figure 3, Item 3) in adapter (Figure 3, Item 1).
3.
Install two wires (Figure 3, Item 2 and 4) on backup alarm sending unit (Figure 3, Item 3) with two screws
(Figure 3, Item 6) and new lockwashers (Figure 3, Item 5).
1
2
3
6
5
4
M1280SWR
Figure 3. Backup Alarm Sending Unit Installation.