HOURMETER PRESSURE SWITCH REPLACEMENT
Figure 2. Hourmeter Pressure Switch Installation.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  903    904    905    906    907  908  909    910    911    912    913  
img
.
TM 5-3895-379-23-1
0171
REMOVAL
NOTE
Use drain pan to catch any oil that may drain from system. Dispose of oil IAW local policy
and ordinances. Ensure all spills are cleaned up.
Cut cable ties as needed.
1.
Disconnect hourmeter pressure switch connector (Figure 1, Item 3) from connector (Figure 1, Item 4).
2.
Remove hourmeter pressure switch (Figure 1, Item 2) from tee (Figure 1, Item 1). Cap tee.
3
2
1
4
M0921SWR
Figure 1. Hourmeter Pressure Switch Removal.
END OF TASK
INSTALLATION
NOTE
Install cable ties as needed.
1.
Install hourmeter pressure switch (Figure 2, Item 2) on tee (Figure 2, Item 1) and tighten to 15-18 lb-ft
(20-25 Nm).
2.
Connect hourmeter pressure switch connector (Figure 2, Item 3) to connector (Figure 2, Item 4).
0171-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00109)