TM 5-3895-379-23-1
0170
REMOVAL - Continued
18.
Remove nut (Figure 6, Item 2), wire (Figure 6, Item 1), and lockwasher (Figure 6, Item 17) from FPM meter
terminal (Figure 6, Item 16). Discard lockwasher.
19.
Remove nut (Figure 6, Item 4), wire (Figure 6, Item 3), and lockwasher (Figure 6, Item 5) from FPM meter
terminal (Figure 6, Item 18). Discard lockwasher.
20.
Remove nut (Figure 6, Item 7), wire (Figure 6, Item 6), and lockwasher (Figure 6, Item 8) from FPM meter
terminal (Figure 6, Item 15). Discard lockwasher.
21.
Remove nut (Figure 6, Item 10), wire (Figure 6, Item 9), and lockwasher (Figure 6, Item 11) from FPM meter
terminal (Figure 6, Item 14). Discard lockwasher.
22.
Remove FPM meter (Figure 6, Item 14) from instrument box assembly.
1
2
3
7
6
4
8
9
3
5
10
17
11
16
15
12
14
13
M0917SWR
Figure 6.
END OF TASK