TM 5-3895-379-23-1
0160
REMOVAL
1.
Remove two screws (Figure 1, Item 1) and washers (Figure 1, Item 5) from operator station (Figure 1, Item 4).
2.
Remove seven screws (Figure 1, Item 1) and washers (Figure 1, Item 2) from operator station
(Figure 1, Item 4).
3.
Lift panel assembly (Figure 1, Item 3) and pull away from operator station (Figure 1, Item 4).
1
3
1
2
2
4
5
1
M0873SWR
Figure 1. Amplitude Select Switch Removal.
4.
Remove nut (Figure 2, Item 1), lockwasher (Figure 2, Item 2), amplitude select switch (Figure 2, Item 5), and
ring (Figure 2, Item 4) from panel assembly (Figure 2, Item 3). Discard lockwasher.