REMOVAL
1.
Remove engine oil sampling valve drain cap (Figure 1, Item 1) from engine oil sampling valve
(Figure 1, Item 2).
NOTE
Use drain pan to catch any oil that may drain from engine oil sampling valve. Dispose of oil
IAW local policy and ordinances. Ensure all spills are cleaned up.
2.
Place drain pan with 1 qt (0.9 Liter) minimum capacity under engine oil sampling valve (Figure 1, Item 2).
3.
Turn and hold knurled knob (Figure 1, Item 10) in direction of arrow and allow remainder of engine oil to drain.
4.
Disconnect hourmeter pressure switch connector (Figure 1, Item 6) from connector (Figure 1, Item 7).
5.
Remove hourmeter pressure switch (Figure 1, Item 5) from tee (Figure 1, Item 4).
6.
Loosen locking nut (Figure 1, Item 9) on engine oil sampling valve (Figure 1, Item 2) and remove engine oil
sampling valve from connector (Figure 1, Item 8).
7.
Remove O-ring (Figure 1, Item 3) from engine oil sampling valve (Figure 1, Item 2). Discard O-ring.
NOTE
Replace any damaged parts.
8.
Remove connector (Figure 1, Item 8) from tee (Figure 1, Item 4).
5
4
3
6
7
2
1
8
10
9
M0112SWR
Figure 1.
Engine Oil Sampling Valve and Fittings Removal.
03/15/2011Rel(1.8)root(maintwp)wpno(M00037)