Figure 1. Water Spray Pump Connector Wiring.
WATER SPRAY PRESSURE IS LOW

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  323    324    325    326    327  328  329    330    331    332    333  
img
. .
TM 5-3895-379-23-1
0069
MALFUNCTION
Water Spray Water Lines Pinched or Damaged.
CORRECTIVE ACTION
Check for pinched or damaged water lines.
a.
If water line(s) is pinched or damaged, replace water line(s) (Volume 2, WP 0273).
b.
If water line(s) is not pinched or damaged, go to Symptom: SPRAY DOES NOT OCCUR IN
EITHER DRUM WHEN WATER SPRAY SWITCH IS IN CONTINUOUS SPRAY
POSITION (WP 0067).
WATER LINES
T0159SWR
Figure 2. Water Spray System Waterlines.
END OF WORK PACKAGE
0069-4
03/15/2011Rel(1.8)root(tswp)wpno(T00075)