WATER SPRAY OCCURS ON ONE DRUM ONLY - Continued
Figure 2. Water Spray System Waterlines.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  322    323    324    325    326  327  328    329    330    331    332  
img
.
TM 5-3895-379-23-1
0069
CORRECTIVE ACTION - Continued
WIRE 200-BK
HARNESS
CONNECTOR
TERMINAL 2
TERMINAL 1
WIRE C922-BR (FRONT)
COVER
PUMP CONNECTOR
WIRE C923-OR (REAR)
WASHER
FRONT SHOWN, REAR SIMILAR
SCREW
T0158SWR
Figure 1.
Water Spray Pump Connector Wiring.
MALFUNCTION
Water Spray Check Valve Plugged.
CORRECTIVE ACTION
Clean and inspect water spray check valve (Volume 2, WP 0274).
a.
If water spray check valve is damaged, replace valve (Volume 2, WP 0274).
b.
If water spray check valve is not damaged, go to next malfunction.
0069-3
03/15/2011Rel(1.8)root(tswp)wpno(T00075)