TM 5-3895-379-23-1
0035
MALFUNCTION
Rear Vibration Sensor Ground Fault.
CORRECTIVE ACTION
WARNING
Remove all jewelry such as rings, dog tags and bracelets. If jewelry contacts
electrical connection, a direct short may occur resulting in injury or death and
damage to equipment.
1.
Disconnect vibration sensor connection from wiring harness connector.
2.
3.
Touch positive (+) probe of multimeter to harness connector (wire 200-BK).
4.
Touch negative (-) probe of multimeter to good ground.
a.
If infinite ohms are measured, repair or replace wire 200-BK and connectors to vibration
b.
If zero ohms are measured, go to next malfunction.
VIBRATION SENSOR
WIRE 440-WH
WIRE 200-BK
HARNESS
CONNECTOR
T0118SWR
Figure 1. Vibration Sensor Wiring.