Figure 1. Batteries.
Figure 3. Battery Disconnect Switch Wiring.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  163    164    165    166    167  168  169    170    171    172    173  
img
. . .
TM 5-3895-379-23-1
0030
MALFUNCTION
Battery Cables Loose, Corroded, or Damaged.
CORRECTIVE ACTION
Check battery cables and connectors for looseness or damage such as corrosion, fraying, broken
terminals, cracked or missing insulation, or kinking.
a.
If battery cable connectors are loose, tighten connectors (WP 0192). If battery cables or
cable connectors are damaged, replace cable(s) (WP 0192).
b.
If battery cables are not damaged and connectors are not loose, lower operator platform
(Volume 2, WP 0235) and go to next malfunction.
STARTER SOLENOID
STARTER
VIEW LOOKING UP
FROM UNDER ROLLER
BATTERY TERMINAL
T0079SWR
Figure 2. Battery Cable Connections at Starter.