TM 5-3895-379-23-1
0030
TROUBLESHOOTING PROCEDURE
SYMPTOM
ROLLER HAS NO ELECTRICAL POWER
MALFUNCTION
CORRECTIVE ACTION
WARNING
To avoid injury, eye protection and acid-resistant gloves must be worn when
working around batteries. Do not smoke, use open flame, make sparks or
create other ignition sources around batteries. If a battery is giving off gases,
it can explode and cause injury to personnel. Remove all jewelry such as rings,
ID tags, watches, and bracelets. If jewelry or a tool contacts a battery terminal,
a direct short will result in instant heating, damage to equipment, and injury.
Sulfuric acid contained in batteries can cause serious burns. If battery corrosion
or electrolyte makes contact with skin, eyes or clothing, take immediate action
to stop the corrosive burning effects. Failure to follow these procedures may
cause injury or death.
1.
Lock steering frame (TM 5-3895-379-10).
2.
Turn battery disconnect switch to ON position (TM 5-3895-379-10).
3.
Set multimeter to measure VDC.
4.
Touch positive (+) probe of multimeter to battery terminal of starter solenoid.
5.
Touch negative (-) probe of multimeter to good ground.
If 24 to 28 VDC are present at battery terminal of starter solenoid, go to Malfunction: No