Figure 1. Main Relay Wiring.
Figure 3. Main Relay Wiring.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  156    157    158    159    160  161  162    163    164    165    166  
img
.
TM 5-3895-379-23-1
0029
MALFUNCTION
No Power To Main Relay Coil.
CORRECTIVE ACTION
1.
Disconnect main relay connector from harness connector.
2.
Turn engine start switch to ON position (TM 5-3895-379-10).
3.
Touch positive (+) probe of multimeter to terminal 1 (wire 308-YL).
4.
Touch negative (-) probe of multimeter to good ground.
If 24 to 28 VDC are not measured at terminal 1 (wire 308-YL) and KEY START fuse is good,
perform the following:
(1)
Turn engine start switch to OFF position (TM 5-3895-379-10).
(2)
Go to Malfunction: No power to engine start switch.
SCREW
PANEL
ASSEMBLY
WASHER
WASHER
WIRE
112-PU
WIRE
SCREW
308-YL
MAIN
WIRE
RELAY
109-OR
HARNESS  MAIN RELAY
CONNECTOR
OPERATOR CONNECTOR
STATION
T0188SWR
Figure 2. Main Relay Wiring.
0029-3
03/15/2011Rel(1.8)root(tswp)wpno(T00035)