APPENDIX O
HESTER
TECHNICAL PUBLICATION CORRECTION
TITLE:
C350B Service Manual
NIMBER:
7109M
CONTRACT NUMBER:
DSA 700-74-C-9024
Make the following corrections to the publication listed above:
1.
SEART NUT reads 100 ft-lbs (13.8 g-m) and should read 26 ft-lbs (3.6 kg-m) maximum. Please note change in
manual.
2.
are attached--please include in the manual.
3.
Figure 7-40, page 7-32 shows two (2) arrows pointing to control pressure port. The top (upper most) arrow is
incorrect. Cross out the upper most arrow.
4.
Figure 7-41, page 7-32 is incorrect. Cross out the entire figure. Case pressure must be checked by tying into the
case drain line on top of the hydrostatic pump.
5.
Figure 7-44, page 7-35 is incorrect. Cross out entire figure. The revised figure is attached - please include in the
manual.
6.
7.
Section 7, paragraph c, page 7-35 reads a dimension of 11/16. Please correct copy to read 1-1/16
8.
include in the manual.
47.