Handling on the Paving Job
Figure 14. Top of fire extinguisher.

Roller, Road, Gasoline Driven, Tandem, 2 Axle, 5 To 8 Ton, Galion Model T5G W/Engine Continental Model F-244
Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
.
Section IV. OPERATION OF MATERIEL USED IN CONJUNCTION WITH THE ROAD ROLLER
36. Fire Extinguisher
a. Description. The fire extinguisher used on the road roller is of a vaporizing liquid type, pump operated, and uses
carbon tetrachloride. The capacity of the fire extinguisher is 1 quart. This fire extinguisher is recommended and suitable
for extinguishing fires on engine and electric equipment.
b. Location. The fire extinguisher is located on the left side of the rear housing.
c. Operation.
(1) In case of fire, remove the fire extinguisher from the road roller.
(2) Turn the pump handle (1, fig. 13) to the left, or counterclockwise, to release it from its locked position.
(3) Hold a finger over the outlet nozzle (4) and work the pump handle (1) 2 or 3 times, first with the outlet nozzle
pointed up,
1
Pump handle
2
Pump valve
3
Body
4
Outlet nozzle
5
Filler cap
6
Shutoff valve
Figure 13. Fire extinguisher.