12.
Install the transfer cart to the housings. Pump the oil
into the housings. For the second cycle, repeat steps 6
through 9. After the second cycle, take an oil sample
before filtering the oil. If the particle count is ISO 19/16
or better, no more flushing is necessary. If the particle
count is higher than ISO 19116 a third flush is needed.
13.
When the flushing is complete, rotate the drum to the
position in order to drain the housings. Remove the
valve and fitting assembly. Drain as much of the oil as
possible.
14.
Rotate the drum until the fill/drain plug is at the top.
Remove the level check plug. Fill the drum to the
correct level. Refer to the Operation and Maintenance
Manual,
"Lubrication
Specifications
and
Refill
Capacities".
NOTE:
The new oil must have a particle count of ISO
18/15 or better
Eccentric Weight Housing Oil Level - Check
SMCS Code:
6606-535-FLV
Illustration 194
1.
Rotate the drum until the welded item (1) is at the
bottom position.
Illustration 195
2.
Remove the level check plug (2). Maintain the oil to the
bottom of the level check plug opening.
Illustration 196
Maintenance Section
Eccentric Weight Housing Oil Level - Check
1-88