TM 5-3895-383-24
Eccentric Weight Housing
SMCS Code: 6606; 6645
Part No.: 140-8267
Illustration 8
(1)
Apply 9S-3263 Thread Lock Compound to the bolt
threads at assembly.
(2)
Torque for the plug.................... 100 5 Nm (74 4 lb-ft)
(3)
Apply 9S-3263 Thread Lock Compound to the bolt
threads at assembly.
(4)
Torque for the plug.........................................100 15 Nm
(74 11 lb-ft)
The weight of the 7X-5305 Shot must total 8.3 kg
(18.3 lb).
(5)
Torque for the two plugs ................................90 15 Nm
(66 11 lb-ft)
NOTE:
In order to fill the reservoir, the position of the
fill/drain plug must be located at the top of the
rotation.
(6)
Rotate the lobe of the weight downward. Orient the
"T" upward on the splined shaft. The total shaft end
play should be .50 mm (0.02 inch) to 1.35 mm (0.05
inch). The assembled housing should be capable of
holding 70 kPa (10 psi) static air pressure and 35 kPa
(5 psi) static vacuum.
NOTE:
Flush
the
eccentric
weight
housing
after
assembly. A level of "ISO 19/16" or less is
required.
11-13