TM 5-3895-382-24
Vibratory Magnetic Sensor (If Equipped)
(1) Clearance between magnetic sensor and gear
tooth ..............................................................1.57 mm (.062 in)
(2) Resistance ........................................................265 ± 30 ohms
Flushing Valve
(1) Charge relief valve:
Pressure setting ..................................... 1725 ± 140 kPa
(250 ± 20 psi)
Torque to install valve into block ........................60 Nm
(45 lb-ft)
(2) Shuttle valve:
Torque to install valve into block ................................90 Nm
(65 lb-ft)
12-8