TM 5-3895-382-24
Charge Filter
(1)
Bypass valve opens at a pressure
differential of.....................................................345 35 kPa
(50 5 psi)
(2)
Visual Bypass Indicator shows red at a
pressure differential of ...................................172 34 kPa
(25 5 psi)
(3)
Tighten filter to a torque of ............................44 3.5 Nm
(32.6 2.6 lb-ft)
NOTE:
The alternative torque for the filter is 3/4 turn past
contact.
Flushing Valve
(1)
Open centered three position shuttle valve
(2)
Charge relief valve:
Pressure setting ........................................ 1725 140 kPa
(250 20 psi)
(3)
Torque to install valve into block ............................60 Nm
(45 lb-ft)
10-11