TM 5-3895-379-23
SEPARATE AND CONNECT VIBRATORY AND PROPEL PUMPS
0186 00
SEPARATE
NOTE
Place vibratory and propel pump assemblies on wooden blocks for ease of access.
1.
Disconnect two hose assemblies (1) from vibratory
control valve (2).
1
2.
Remove six bolts (3) from vibratory control valve (2)
and vibratory pump (4).
5
3.
Remove vibratory control valve (2) and spacer (5)
4
from vibratory pump (4).
2
4.
Remove four O-rings (6) from spacer (5) and vibra-
3
tory control valve (2). Discard O-rings.
4
5.
Remove two bolts (7) and separate vibratory pump (3)
1
from propel pump (8).
401-2025a
CONNECT
1.
Connect propel pump (8) to vibratory pump (4) with
two bolts (7).
1
2.
Install four new O-rings (6) on spacer (5) and vibra-
tory control valve (2).
3.
Install vibratory control valve (2) and spacer (5) on
vibratory pump (4).
4.
Install six bolts (3) on vibratory control valve (2) and
vibratory pump (4).
5.
Connect two hose assemblies (1) to vibratory control
valve (2).
401-2025b
67 8
6.
END OF WORK PACKAGE
0186 00-2