TM 5-3895-379-23
VIBRATORY AND PROPEL PUMPS REPLACEMENT - CONTINUED
0187 00
INSTALLATION
NOTE
Use lifting device to position vibratory and propel pumps.
1.
Install with two bolts (20) to roller.
2.
Install valve (19) to propel pump (6).
3.
Install nut (16) and bolt (17) that fasten clip (18) to hose assemblies (2) and (15).
4.
Connect two hose assemblies (14) to vibratory pump (10).
5.
Connect three hose assemblies (15) to propel pump (6).
6.
Install cable tie and move wiring harness (13) aside from vibratory control valve (3).
7.
Install two electrical connectors (12) and two screws (11) to vibratory control valve (3).
8.
Install two electrical connectors (9) and two screws (8) to vibratory pump (10).
9.
Connect two electrical connector wires (7).
10.
Connect hose assemblies (4) and (5) to propel pump (6).
11.
Connect four hose assemblies (1) and hose assembly (2) to vibratory control valve (3).
12.
13.
14.
Close left-side door assembly (TM 5-3895-379-10).
END OF WORK PACKAGE
0187 00-3/(0187 00-4 Blank)