TM 5-3895-379-23
WATER SPRAY STRAINER ASSEMBLY MAINTENANCE - CONTINUED
0150 00
CLEANING/INSPECTION
1.
Clean fittings, bushings, valve and strainer assembly with detergent and water. Remove difficult deposits with
cleaning brush.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components. DO NOT
direct compressed air against human skin. Failure to follow this warning may cause injury or death. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user must wear
protective goggles or face shield.
2.
Use a cleaning cloth or compressed air to dry metal parts.
3.
Check fittings, bushings and valve for clogging, corrosion or excessive wear.
4.
Check strainer assembly for clogging, corrosion, excessive wear and obvious signs of damage.
5.
Check all parts for stripped or damaged threads.
6.
Replace all damaged parts.
ASSEMBLY
NOTE
CB534C Roller does not have valve or adapters.
Apply sealing compound to threads of two bushings (13) and install two bushings (13), valve (12) (CB534B Roller)
and two adapters (8) in strainer assembly (10).
INSTALLATION
1.
If removed, install hose clamp (9) on bumper assembly (11).
2.
Install strainer assembly (10) in hose clamp (9). Tighten clamp.
CAUTION
Directional arrows on strainer assembly
must point left when strainer assembly is
installed. Arrows indicate direction of
water flow through strainer assembly. Fail-
ure to position strainer assembly arrow
pointing left will result in poor equipment
performance and possible equipment dam-
4
age.
3
3.
Position two tubes (6) and (7) on adapters (8) and
2
tighten two fittings (5).
1
4.
Install cover (3) on bumper assembly (4) with four
washers (2) and bolts (1). Tighten screws to 15-25
401-763
lb-ft (20-34 Nm).
5.
Fill water spray system (TM 5-3895-379-10).
6.
Start engine, operate water spray system (TM 5-3895-379-10) and check for leaks.
7.
Remove chocks (TM 5-3895-379-10).
END OF WORK PACKAGE
0150 00-3/(0150 00-4 Blank)