TM 5-3895-379-23
ROLLOVER PROTECTION STRUCTURE (ROPS) ASSEMBLY REPLACEMENT - CONTINUED
0126 00
INSTALLATION - CONTINUED
5.
Install three handrail assemblies (8), (9) and (10) on ROPS assembly (4) with six washers (12) and bolts (11). Turn
bolts until snug, but do not tighten bolts.
6.
Install three handrail assemblies (8), (9) and (10) on ROPS assembly (4) and frame assembly (7) with three washers
(6) and bolts (5). Tighten bolts to 518-666 lb-ft (702-903 Nm).
7.
Tighten six bolts (11) to 65 lb-ft (88 Nm).
8.
Install rear handrail assembly (3) on ROPS assembly (4) with four washers (2) and bolts (1). Tighten bolts to 45 lb-ft (61
Nm).
11
12
2
1
4
3
8
10
9
4
8
3
8
6
5
7
401-693
9.
Remove chocks (TM 5-3895-379-10).
END OF WORK PACKAGE
0126 00-4