TM 5-3895-379-23
INSTRUMENT WIRING HARNESS REPLACEMENT - CONTINUED
0112 00
INSTALLATION - CONTINUED
19.
Install three new lockwashers (32), wires (29), (30) and (31) and nuts (28) on VPM tachometer terminals (33), (34) and
(35).
20.
Install lamp assembly (26) in VPM tachometer (27).
28
28
32
30
29
34
28
32
33
31
35
32
26
27
401-604
21.
Carefully position instrument box assembly (4) and instrument wiring harness assembly (15) on operator station (7).
22.
Connect connector (24) to connector (25).
23.
Connect connector (22) to connector (23).
24.
Connect connector (20) to connector (21).
25.
Connect connector (18) to connector (19).
26.
Connect connector (16) to connector (17).
27.
Position clamp (13) on instrument wiring harness assembly (15).
28.
Install clamp (13) on operator station stud (14) with washer (12) and new locknut (11).
15
14
4
13
24
12
22
11
20
21
16
25
18
17
23
19
13
401-603
0112 00-13