TM 5-3895-379-23
BATTERY CABLE REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Materials/Parts
Battery disconnect switch in OFF position (TM 5-
3895-379-10)
References
Right side door assembly opened (TM 5-3895-379-
TM 5-3895-379-23P, Figure 55
10)
WARNING
To avoid injury, eye protection and acid-resistant gloves must be worn when working around batteries.
Do not smoke, use open flame, make sparks or create other ignition sources around batteries. If a battery
is giving off gases, it can explode and cause injury. Remove all jewelry such as rings, ID tags, watches,
and bracelets. If jewelry or a tool contacts a battery terminal, a direct short will result in instant heating,
damage to equipment, and injury.
Sulfuric acid contained in batteries can cause serious burns. If battery corrosion or electrolyte makes
contact with skin, eyes or clothing, take immediate action to stop the corrosive burning effects. Failure
to follow these procedures may cause injury or death.
CAUTION
Always disconnect negative (-) battery cable before servicing battery or positive (+) battery cable. Fail-
ure to do so can result in damage to electrical system.
Do not allow battery cable ends to contact each other or roller. Failure to follow this caution may cause
damage to battery or electrical system.