TM 5-3895-379-23
STARTING AID SWITCH REPLACEMENT - CONTINUED
0078 00
REMOVAL - CONTINUED
NOTE
Tag and mark all wires prior to removal.
4.
Remove two screws (8), wires (9) and lockwashers (10) from starting aid switch (11). Discard lockwasher.
5.
Remove nut (12) and lockwasher (13) from starting aid switch (11). Discard lockwasher.
6.
Remove starting aid switch (11) and ring (14) from instrument box assembly (4).
7.
Remove locking ring (14) from starting aid switch (11).
12
9
10
TAB
8
NOTCH
13
4
11
9
14
11
401-470
INSTALLATION
NOTE
Tab or ring fits in notch of instrument box assembly to properly align starting aid switch.
1.
Position ring (14) on starting aid switch (11).
2.
Position ring (14) and starting aid switch (11) on instrument box assembly (4).
3.
Install new lockwasher (13) and nut (12) on starting aid switch (11).
4.
Install two new lockwashers (10) and wires (9) on starting aid switch (11) with screws (8).
0078 00-2