TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Vibratory System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Vibration Does Not Occur While 3. Check for power at amplitude 1. If 24 to 28 Vdc are not measured
9.
select switch. Set amplitude
at terminals 1 and 3, turn engine
Amplitude Select Switch Is Set To High
select switch to high pitch (push
start switch and battery disconnect
Pitch- Continued.
forward). Touch positive (+)
switch to OFF position (TM 5-
3895-379-10). Replace amplitude
(wire B921-WH) and negative
ground. Measure Vdc. Set 2. If 24 to 28 Vdc are measured at
terminals 1 and 3, repair or replace
amplitude select switch to low
wiring and connectors from
pitch (pull back). Touch positive
(+) probe of multimeter to
terminal 3 (wire C920-GN) and
negative (-) probe of multimeter
to good ground.
PANEL
ASSEMBLY
SCREW
WIRE C920-GN
WASHER
SCREW
TERMINAL 3
WASHER
WIRE
C933-GN
WIRE
B921-WH
TERMINAL 1
TERMINAL 2
AMPLITUDE SELECT SWITCH
OPERATOR STATION
401-229
0006 00-118