Table 6. Vibratory System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Vibration Only Occurs While Vibration 3. Check for power at vibration 1. If 24 to 28 Vdc are not measured
8.
control switch. Push vibration
at terminal 1 (wire B934-BU), turn
Control Switch Is Set To Automatic
control switch forward to
engine start switch and battery
Mode - Continued.
automatic (AUTO) position.
disconnect switch to OFF position
Touch positive (+) probe of
(TM 5-3895-379-10). Replace
B934-BU) and negative (-) probe
2. If 24 to 28 Vdc are measured at
terminal 1 (wire B934-BU), turn
engine start switch and battery
disconnect switch to OFF position
(TM 5-3895-379-10). Install panel
on operator station with nine
screws and washers and notify
supervisor.
PANEL
ASSEMBLY
SCREW
WIRE C933-GN
WASHER
SCREW
WASHER
TERMINAL 3
WIRE
B932-YL
WIRE B934-BU
TERMINAL 1
VIBRATION CONTROL
TERMINAL 2
SWITCH
OPERATOR STATION
401-228
0006 00-115