TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. Work Lights and Gauge Lights Do Not
Operate - Continued.
SCREW
PANEL ASSEMBLY
WASHER
WIRE 112-PU
WIRE 114-GN
WASHER
SCREW
LIGHTS
CIRCUIT
BREAKER
OPERATOR
STATION
401-210
3. Battery disconnect and start 1. If 24 to 28 Vdc are not measured
switches in ON position (TM 5-
at terminal B (wire 114-GR), turn
3895-379-10). Check for power
engine start switch and battery
to work light control switch.
disconnect switch to OFF position
Touch positive (+) probe of
(TM 5-3895-379-10). Repair or
replace wire 114-GR and
114-GR) of lights circuit breaker
connectors from lights circuit
and negative (-) probe of
breaker to work light control
2. If 24 to 28 Vdc are measured at
input terminal B (wire 114-GR),
replace work light control switch
TERMINAL B
WIRE 114-GR
WIRE 619-GN
WIRE 614-PU
WIRE 809-GN
401-211
0006 00-82