TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Alternator Indicator Is On - Continued. 6.
Check for defective battery 1. If
infinite ohms are not present
8
disconnect switch. Turn battery
across battery disconnect switch
disconnect switch OFF (TM 5-
terminals in disconnect position,
3895-379-10). Remove nut,
replace battery disconnect switch
lockwasher and cable from
battery-side terminal. Discard
measure ohms. Touch positive 2. If infinite ohms are present across
battery disconnect switch in
connect position, replace battery
battery-side
terminal
and
negative (-) probe of multimeter
Lower operator platform (WP
to frame-side terminal of battery
disconnect switch. Multimeter
should measure infinite ohms.
3. If both ohms checks are OK, install
Turn battery disconnect switch
cable on battery disconnect switch
with lockwasher and nut. Replace
zero ohms.
BATTERY DISCONNECT SWITCH
BATTERY-SIDE
TERMINAL
NUT
LOCK-
WASHER
CABLE
FRAME-SIDE
TERMINAL
401-208
0006 00-78