TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check ground connection at fuel 1. If infinite ohms are measured,
12. Fuel Gauge Does Not Work.
level sending unit. With
repair or replace wire 200-BK and
multimeter set to measure ohms,
connectors to fuel level sending
touch positive (+) probe of
negative (-) probe of multimeter 2. If zero ohms are measured, go to
Step 2.
to good ground.
WIRE 447-PK
WIRE 200-BK
401-214