WATER SPRAY PIPE ASSEMBLY MAINTENANCE

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 2 Page Navigation
  268    269    270    271    272  273  274    275    276    277    278  
img
. . .
TM 5-3895-379-23-2
0266
INSTALLATION
1.
Install 24 bolts (Figure 2, Item 5), washers (Figure 2, Item 4), and nuts (Figure 2, Item 3) that fasten six mounts
(Figure 2, Item 1) to drum assembly (Figure 2, Item 2).
2.
Attach lifting device straps with link bracket to plate (Figure 2, Item 9) and support (Figure 2, Item 6). Install
24 bolts (Figure 2, Item 7) and washers (Figure 2, Item 8) that fasten plate (Figure 2, Item 9) to mounts
(Figure 2, Item 1) and install plate (Figure 2, Item 9) and support (Figure 2, Item 6), as a unit, to drum assembly
(Figure 2, Item 2).
2
1
9
8
7
43
5
6
M1209SWR
Figure 2. Resilient Drum Mounts Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install propel motor. (Volume 1, WP 0204)
2.
Install vibratory motor. (WP 0252)
3.
Install supports (bumpers). (WP 0229)
4.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE