TM 5-3895-379-23-1
0177
INSTALLATION
1.
Install four lamps (Figure 4, Item 3) in lamp assemblies (Figure 4, Item 4).
2.
Install four lamp assemblies (Figure 4, Item 4) in functional indicator light assembly (Figure 4, Item 2).
3.
Position functional indicator light assembly (Figure 4, Item 2) on instrument box assembly (Figure 4, Item 1).
NOTE
Before installing functional indicator light assembly bracket on functional indicator light
assembly, ensure functional indicator light assembly is positioned so icons are right-side up
when instrument box assembly is installed.
4.
Install functional indicator light assembly bracket (Figure 4, Item 5) on stud (Figure 4, Item 8) with new
lockwasher (Figure 4, Item 6) and nut (Figure 4, Item 7).
1
2
3
8
4
5
6
7
M1202SWR
Figure 4. Functional Indicator Light Installation.
03/15/2011Rel(1.8)root(maintwp)wpno(M00115)