FUSE AND FUSE HOLDER REPLACEMENT
Figure 3. Fuse and Fuse Holder Removal.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  859    860    861    862    863  864  865    866    867    868    869  
img
.
TM 5-3895-379-23-1
0164
REMOVAL - Continued
3.
Remove two shoulder screws (Figure 2, Item 1), washers (Figure 2, Item 2), and vandal guard
(Figure 2, Item 3) from instrument box assembly (Figure 2, Item 7).
4.
Remove three screws (Figure 2, Item 6) and washers (Figure 2, Item 5) from operator station
(Figure 2, Item 4).
5.
Lift and tilt back instrument box assembly (Figure 2, Item 7) to gain access to back of instrument box assembly.
3
2
1
7
6
5
4
M0888SWR
Figure 2. Fuse and Fuse Holder Removal.
NOTE
Tag and mark all wires prior to removal.
6.
Cut two wires (Figure 3, Item 2) and remove from fuse holder assembly (Figure 3, Item 1).
7.
Remove nut (Figure 3, Item 4) from fuse holder assembly (Figure 3, Item 1).
8.
Remove fuse holder assembly (Figure 3, Item 1) and seal (Figure 3, Item 5) from instrument box assembly
(Figure 3, Item 3). Discard seal.