TM 5-3895-379-23-1
0037
MALFUNCTION
Work Light Control Switch Fault or Circuit Wiring Faulty.
CORRECTIVE ACTION
1.
Touch positive (+) probe of multimeter to terminal B (wire 114-GR) of lights circuit breaker.
2.
Touch negative (-) probe of multimeter to good ground.
3.
Turn engine start switch to OFF position (TM 5-3895-379-10).
4.
Turn battery disconnect switch to OFF position (TM 5-3895-379-10).
a.
If 24 to 28 VDC are not measured at terminal B (wire 114-GR), repair or replace
wire 114 - GR and connectors from lights circuit breaker work light control switch
b.
If 24 to 28 VDC are measured at input terminal B (wire 114-GR), replace work light control
TERMINAL B
WIRE 114-GR
WIRE 619-GN
WIRE 614-PU
WIRE 809-GN
T0113SWR
Figure 3. Work Light Control Switch Wiring.
END OF WORK PACKAGE
03/15/2011Rel(1.8)root(tswp)wpno(T00043)