0036
MALFUNCTION
Hourmeter Pressure Switch Faulty.
CORRECTIVE ACTION
1.
Connect a jumper wire from terminal 1 to terminal 2 of harness connector.
2.
Turn battery disconnect switch to ON position (TM 5-3895-379-10).
3.
Turn engine start switch to ON position (TM 5-3895-379-10).
4.
Observe warning and indicator lights for proper operation.
5.
Turn engine start switch to OFF position (TM 5-3895-379-10).
6.
Turn battery disconnect switch to OFF position (TM 5-3895-379-10).
7.
Remove jumper wire.
a.
If warning and indicator light operate, replace hourmeter pressure switch (WP 0171).
b.
If warning and indicator light do not operate, connect harness connector to hourmeter
pressure switch connector, and go to next malfunction.