FEET PER MINUTE (FPM) METER DOES NOT WORK (CB534C) - Continued
FUEL GAUGE DOES NOT WORK

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  143    144    145    146    147  148  149    150    151    152    153  
img
. . .
TM 5-3895-379-23-1
0026
MALFUNCTION
No Power To Feet Per Minute (FPM) Meter.
CORRECTIVE ACTION
1.
Set multimeter to measure VDC.
2.
Turn engine start switch to ON position (TM 5-3895-379-10).
3.
Touch positive (+) probe of multimeter to terminal + (wire 123-WH) of FPM meter.
4.
Touch negative (-) probe of multimeter to good ground.
a.
If 24 to 28 VDC are not measured at terminal + (wire 123-WH) and GAUGES fuse is good,
repair or replace wiring and connectors to GAUGES fuse holder (WP 0195).
b.
If 24 to 28 VDC are present at terminal + (wire 123-WH), replace FPM meter (WP 0170).
123-WH
614-PU
200-BK
449-WH
T0121SWR
Figure 1.
Feet Per Minute (FPM) Meter Wiring.
END OF WORK PACKAGE
0026-3/4 blank
03/15/2011Rel(1.8)root(tswp)wpno(T00032)