• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
FUEL GAUGE DOES NOT WORK - Continued
Figure 2. Fuel Gauge Wiring.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  147    148    149    150    151  152  153    154    155    156    157  
img
.
TM 5-3895-379-23-1
0027
MALFUNCTION
No Power To Fuel Level Gauge.
CORRECTIVE ACTION
1.
Remove two shoulder screws, washers, and vandal guard from box assembly.
2.
Remove three screws and washers and lift box assembly up from operator station.
3.
Turn battery disconnect switch to ON position (TM 5-3895-379-10).
4.
Turn engine start switch to ON position (TM 5-3895-379-10).
5.
Set multimeter to measure VDC.
6.
Touch positive (+) probe of multimeter to terminal + (wire 123-WH) of fuel level gauge.
7.
Touch negative (-) probe of multimeter to good ground.
8.
Turn engine start switch to OFF position (TM 5-3895-379-10).
9.
Turn battery disconnect switch to OFF position (TM 5-3895-379-10).
If 24 to 28 VDC are not present at terminal + (wire 123-WH), and GAUGES fuse is good,
replace or repair wiring and connectors to GAUGES fuse holder (WP 0195).
0027-4
03/15/2011Rel(1.8)root(tswp)wpno(T00033)


Privacy Statement