TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
9. Engine is Using More Fuel Than Usual.
1. Open left-side door assembly
a. If air cleaner primary element is
clogged, clean by tapping
filter service indicator for red
element with hand to remove
indication in viewing window.
dirt. Install secondary and
Red indicates a clogged air
primary filter elements and
cleaner primary or secondary
cover and close two air cleaner
element. If filter service
housing latches. Reset air filter
indicator shows red in viewing
service indicator. Close left-side
window, unlatch two air
cleaner housing latches and
remove
cover.
Remove
primary
and
secondary
elements from air cleaner
housing.
b. If air cleaner primary element
is torn or ripped, notify
supervisor for replacement.
Install secondary and primary
filter elements and cover and
close two air cleaner housing
latches. Reset air filter service
indicator. Close left-side door
SECONDARY
AIR FILTER SERVICE
HOUSING
ELEMENT
INDICATOR
SERVICE
SERVICE
PRIMARY
WHEN
WHEN
ELEMENT
RED
LEVEL IS
AT 22
VIEWING
WINDOW
HOUSING LATCHES
401-084
HOUSING COVER