TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
a. If air cleaner primary element
3. Engine is Sluggish - Continued.
5. Check air filter service
is clogged, clean by tapping
indicator for red indication in
element with hand to remove
viewing
window.
Red
dirt. Install secondary and
indicates a clogged air cleaner
primary filter elements and
primary or secondary element.
cover and close two air cleaner
If filter service indicator shows
housing latches. Reset air filter
red in viewing window,
service indicator. Close left-
unlatch two air cleaner
housing latches and remove
cover. Remove primary and
secondary elements from air
cleaner housing.
b. If air cleaner primary element
is torn or ripped, notify
supervisor for replacement.
Install secondary and primary
filter elements and cover and
close two air cleaner housing
latches. Reset air filter service
indicator. Close left-side door
SECONDARY
AIR FILTER SERVICE
HOUSING
ELEMENT
INDICATOR
SERVICE
SERVICE
PRIMARY
WHEN
WHEN
ELEMENT
RED
LEVEL IS
AT 22
VIEWING
WINDOW
HOUSING LATCHES
401-084
HOUSING COVER
0010 00-13